Simpson 260 Series 8 Analog Multimeter with Calibration

Simpson 260 Series 8 Analog Multimeter with Calibration

SIMPSON

Call For Pricing
Available to order
EDMO # 260-8 CAL
MFR Part # 260-8 CAL
Need help placing an order? Call 800-235-3300 or Contact us

Product Description

The 260-8 Analog VOM offers more features than its predecessors, combining quality and affordability with standard and high-energy fusing and a diode network for meter movement protection. It supports AC and DC voltage and current measurements, as well as resistance testing. Standard-size reverse/recessed safety jacks prevent operator or tool contact with the instrument’s electrical connections. The phenolic case features heavy reinforced walls for maximum durability, while the self-shielding taut band adds shock resistance to the meter movement. Portable enough to carry yet maintaining benchtop-level accuracy, it uses two knobs to control range and function selection. Full-size test leads with threaded probe tips allow screw-on alligator clips, eliminating the need to change leads while working.

This 260-8 Analog VOM (EDMO 260-8 CAL) includes calibration.

Features

  • Easy to operate — two knobs control the selection of functions and ranges
  • More than 20 measurement ranges for DC voltage and current, AC voltage and current, resistance
  • Large, tri-colored dial with mirrored scale to prevent parallax error
  • Reverse recessed safety jacks prevent operator and tool contact with electrical connections
  • Rugged phenolic case with reinforced walls for maximum durability
  • Self-shielding taut-band meter movement provides added shock resistance

Specifications

  • Weight:
    3 lbs (1.4 kg)
  • Size:
    7 x 5.5 x 3.1 in (18 x 14 x 8 cm)
  • Batteries:
    1.5V D, 9V (Neda No.13F, 1604A)
  • Fuse:
    F1 1A, 250V, type 3AG, quick acting Littlefuse® Type 312001 F2 2A, 600V Littlefuse® Type BLS or 2A 600V, Bussman® Type BBS
  • Rated Circuit-To-Ground Voltage:
    1000V AC/DC Max
  • DC Voltage Ranges:
    250 mV, 1 V, 2.5 V, 10 V, 25 V, 50 V, 250 V, 500 V, 1000 V
  • DC Voltage Accuracy:
    2% of full scale
  • DC Voltage Sensitivity:
    20 KΩ per volt
  • AC Voltage Ranges:
    2.5 V, 10 V, 25 V, 50 V, 250 V, 500 V, 1000 V
  • AC Voltage Accuracy:
    3% of full scale
  • AC Voltage Sensitivity:
    5 KΩ per volt
  • Decibel Range:
    -20 dB to 50 dB
  • Reference:
    0 dB = 1 mW into 600 Ω
  • AC Current:
    Up to 250 AC amperes with AC Amp-Clamp Adapter Accessory 00545
  • DC Current Ranges:
    50 μA, 1 mA, 10 mA, 100 mA, 500 mA, 10 A
  • DC Current Accuracy:
    1.5% of full scale 50 μA, 2.0% full scale, all others
  • DC Current Voltage Drop (Nominal):
    250 mV on 50 μA/1 mA; 255 mV on 10 mA/10 A; 300 mV on 100 mA; 500 mV on 500 mA
  • Resistance Ranges:
    Rx1, Rx100, Rx10K
  • Resistance Accuracy:
    Rx1: 2.5º of arc Rx100: 2.0º of arc Rx10K: 2.0º of arc
  • Resistance Maximum Indication:
    Rx1: 0 – 2K'Ω Rx100: 0 – 200K'Ω Rx10K: 0 – 20M'Ω